SHENZHEN URILIC ENERGY TECHNOLOGY CO.,LTD

10 YEARS OF INDUSTRY EXPERIENCE ! URILIC ENERGY, CREATE NEW NATURE

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHybrid Solar And Wind Power Generation

High - Tech Hybrid Solar And Wind Power Generation / Hybrid Wind Turbine

High - Tech Hybrid Solar And Wind Power Generation / Hybrid Wind Turbine

    • High - Tech Hybrid Solar And Wind Power Generation / Hybrid Wind Turbine
    • High - Tech Hybrid Solar And Wind Power Generation / Hybrid Wind Turbine
  • High - Tech Hybrid Solar And Wind Power Generation / Hybrid Wind Turbine

    Product Details:

    Place of Origin: China
    Brand Name: URILIC
    Certification: ISO9001,CE,UL,IEC
    Model Number: Communication Base Station Power Supply System

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable
    Packaging Details: Multiple packaging
    Delivery Time: 5-30 work days
    Payment Terms: T/T
    Supply Ability: 500 sets/ month
    Contact Now
    Detailed Product Description
    Product Name: Hybrid Solar And Wind Power Generation Wind Turbine: 600W, 1000W, 1500W, 2000W
    Solar Panel: According To Configuration Voltage: 48V
    Battery: Lead-acid Batteries Or Lithium Batteries Battery Voltage: 2V, 6V, 12V
    Power Supply: Continuous Power Supply System: Communication Base Station
    High Light:

    wind turbine and solar panel hybrid system

    ,

    hybrid solar wind power generation system

    Mobile Communication Base Station Equipment Hybrid Solar And Wind Power Generation
     
    Base station power supply system is one of the supporting systems for mobile main equipment and transmission equipment, involving power.
    Many professional knowledge such as mechanics, chemistry, electronic communication and automatic control technology, computer application and so on. The purpose of its maintenance work is to ensure that communication equipment can obtain sustained, stable and reliable energy, to provide a normal operating environment for communication equipment, and to ensure the safety of the system. In this regard, maintenance personnel need to have certain professional skills.
     
    There are many kinds of power supply equipment, which are greatly influenced by external factors. If the maintenance is not effective, the overall failure rate of the equipment will be very high. The power environment monitoring system will lose its effectiveness, the operation cost is high, and the base station is not safe. In order to reduce operating costs and prevent the early abandonment of batteries, this paper analyses the electric environment of base station and the key points of power maintenance, and puts forward solutions.
     
     
    Application Factors of Mobile Communication Base Station Equipment Hybrid Solar And Wind Power Generation

    In the whole communication industry, the environment of mobile communication base station is more complex. Due to the restriction of the environment conditions of base station, the requirements of construction and configuration are different, and maintenance requirements are different. For example, many base stations are built on high buildings or high mountains. Objectively speaking, most of the urban power environment of base stations is not as high as that of exchange bureaus, but the quality of batteries is higher, which adds many difficulties to the configuration, maintenance and management of batteries. If improper maintenance, it will cause the early failure of batteries.

     

    Battery:

    Battery maintenance is the focus of the whole power supply maintenance work. All power supply maintenance is carried out around this work. Generally speaking, the key to the maintenance of VRLA batteries is to control the temperature of the environment and the charging and discharging of the batteries. Therefore, controlling the charging and discharging of the batteries is an important link in the maintenance of the batteries. Battery charging is divided into floating charging and balanced charging. The so-called floating charge refers to the parallel operation of storage battery and switching power supply when the city electricity is normal. The output voltage of switching power supply meets the requirements of battery manufacturers, generally 2.23V/unit, which is used to meet the needs of self-discharge and oxygen cycle of batteries. By definition, floating charge voltage can only meet the needs of self-discharge and oxygen cycle of battery, and can not be used as supplementary charge after battery discharge. Supplementary charging of batteries is accomplished by balanced charging of switching power supply. When charging equally, the charging voltage is increased to 2.35V~2.40V/battery, and the battery is charged with current less than or equal to 0.10C10A. The control of charging process is realized by setting the switching power supply and intelligent control of the switching power supply. In daily maintenance, it can be checked regularly by the power environment monitoring system to prevent the change of rectifier parameters and battery damage.

     

    Hot-selling Maglev Vertical Axis Wind Turbine

    Items

    60024/48

    100024/48

    Rated power

    600W

    1000W

    Dimension
    (Height/Diameter)

    Ø1100/1250

    Ø1500/1760

    Weight

    32kg / 35kg

    55 kg / 57kg

    Blade material

    Aluminum Alloy

    Aluminum Alloy

    Blade quantity

    3

    3

    Swept area ㎡

    1.2

    1.8

    Min starting wind speed

    1.3m/s

    1.5 m/s

    Cut-in wind speed

    2 7m/s

    3.5m/s

    Rated wind speed

    12m/s

    13m/s

    Cut-off wind speed

    15m/s

    15m/s

    Survival wind speed

    65m/s

    60m/s

    Generator type

    AC,3Phases

    AC,3Phases

    Controller Output Voltage

    24V/48V

    24V/48V

    Controller Braking System

    3-phase short circuit by NFB brake

    3-phase short circuit by NFB brake

    Ambient Temperature

    -40~50 ℃

    -40~50 ℃

    Noise

    Noisy from National Machinery Quality Inspection Centre at 12m/s : <40db