    Product Details:

    Place of Origin: China
    Brand Name: URILIC
    Certification: ISO9001,CE,UL,IEC
    Model Number: Communication Base Station Power Supply

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable
    Packaging Details: Multiple packaging
    Delivery Time: 5-30 work days
    Payment Terms: T/T
    Supply Ability: 500 sets/ month
    Contact Now
    Detailed Product Description
    Product Type: Hybrid Solar And Wind Power Generation Solar Panel: Design As Needed
    Wind Turbine: 600W, 1000W, 1500W, 2000W Voltage: 48V
    Design Life: At Least 20 Years Usage: Off Grid, Telecoms BTS, Mountain, Island
    Power Supply: Continuous Power Supply System Install: Installed In Italy
    High Light:

    wind turbine and solar panel hybrid system

    ,

    hybrid solar wind power generation system

    Communication Base Station Hybrid Solar And Wind Power Generation Installed in Italy

     

    Communication hybrid solar and wind power generation system is an integral part of the communication system, often referred to as the "heart" of the communication system, and plays an extremely important role in the communication system. If the communication hybrid solar and wind power generation system fails, the quality of power supply will be reduced or the power supply will be interrupted, and the communication system will not work properly, which will inevitably lead to the failure of the communication system. The failure of communication system will cause enormous economic loss and immeasurable political impact. Therefore, for Telecom operators, in a sense, communication power supply is the most important thing in the work. It can be said that without communication hybrid solar and wind power generation, there will be no communication business and no economic benefits. Therefore, in order to ensure the smooth communication, we must pay enough attention to the communication hybrid solar and wind power generation and take various necessary measures to achieve the high availability of the communication hybrid solar and wind power generation.

     

     

     

    In order to ensure the high availability of communication hybrid solar and wind power generation, the communication hybrid solar and wind power generation system must have the following four key elements.
    (1) Reliability
    It is required that all kinds of hybrid solar and wind power generation equipment, switches, switching switches and other distribution equipment must be very reliable and have a high average failure-free time index. In the design of communication hybrid solar and wind power generation system, we strive for simplicity and adopt the design method of eliminating or reducing single point faults.
    (2) Functionality
    It is required that all kinds of power supply equipment must be able to supply power steadily, and the output indicators meet the quality requirements. Over-high power supply voltage will cause damage to components of communication load equipment, and over-low power supply voltage will affect the normal operation of communication system. Excessive weighting noise voltage of DC power supply system will affect the quality of telephone calls, and excessive fluctuating voltage will increase the bit error rate of data communication equipment. UPS AC uninterruptible power supply should be able to suppress all kinds of interference of municipal power supply, interference may cause the decline of Internet transmission rate, data loss, and even lead to network paralysis.
    (3) Maintainability
    The design of communication power supply system must enable all components of power supply system to be maintained under the condition of normal power supply of communication system, which is generally called "simultaneous maintenance". That is to say, one part of the equipment of communication hybrid solar and wind power generation system maintains another part of the power supply equipment while it is in normal operation.
    (4) Fault Tolerance
    Communication hybrid solar and wind power generation system must have the ability to resist faults, so that failure of any component of hybrid solar and wind power generation system will not affect the normal operation of power supply and communication load equipment, and the whole distribution system must also have the ability to resist faults, so as to make up for the inevitable load faults and human operation errors. Ring.

     

    Hot-selling Maglev Vertical Axis Wind Turbine:

    Items

    60024/48

    100024/48

    Rated power

    600W

    1000W

    Dimension
    (Height/Diameter)

    Ø1100/1250

    Ø1500/1760

    Weight

    32kg / 35kg

    55 kg / 57kg

    Blade material

    Aluminum Alloy

    Aluminum Alloy

    Blade quantity

    3

    3

    Swept area ㎡

    1.2

    1.8

    Min starting wind speed

    1.3m/s

    1.5 m/s

    Cut-in wind speed

    2 7m/s

    3.5m/s

    Rated wind speed

    12m/s

    13m/s

    Cut-off wind speed

    15m/s

    15m/s

    Survival wind speed

    65m/s

    60m/s

    Generator type

    AC,3Phases

    AC,3Phases

    Controller Output Voltage

    24V/48V

    24V/48V

    Controller Braking System

    3-phase short circuit by NFB brake

    3-phase short circuit by NFB brake

    Ambient Temperature

    -40~50 ℃

    -40~50 ℃

    Noise

    Noisy from National Machinery Quality Inspection Centre at 12m/s : <40db

     

    Design Concept:

    • The wind turbine is small in size, light in weight, convenient in transportation, and suitable for environmental transportation in the wild and mountains. Such as: 500W, 600W, 1000W, 1500W;
    • The output voltage of the wind turbine is high, and the charging effect of the breeze power generation is excellent;
    • Long service life and low maintenance rate.
    • Reliable performance, long life and long battery life; economical safety compared with laying power lines; low failure rate and easy maintenance.

     

    Application of Hybrid Solar And Wind Power Generation:

    It is suitable for a variety of communication application scenarios including mountain communication base station, Island communication base station, remote communication base station, roof station, commercial roof base station, outdoor macro station, outdoor micro station and indoor base station.                                                         Communication Base Station Wind Turbine Solar Panels Hybrid System Lightweight

    Contact Details
    ShenZhen URILIC ENERGY Technology Co.,Ltd

    Contact Person: sales

    Send your inquiry directly to us (0 / 3000)